ParaZapper ® UZI-3c Instructions and Specifications
The ParaZapper ® UZI-3c is a microprocessor based multi-frequency zapper designed with improved results in consideration. This zapper includes the equivalent or better than all of the most popular zappers in one package at an affordable cost with a constant 10.6 volt ( +/- 0.25 V ) output without the risks associated with using a wall adapter. The output is strong and this unit is intended for those uses that need a stronger output as well as more numerous and more accurate frequencies. It also includes new innovations, such as pedestal offset, that offer significant enhancements over other zappers. One frequency alone does not provide the best overall coverage for multiple types of micro-organisms. Two frequencies can double the chance of hitting a particular organisms resonance, but even this does not provide the best coverage. For that reason, we have selected several Rife (Mode 1 and 4) frequencies along with Hulda Clark Zapper frequencies (mode 2), Don Croft's Terminator Zapper (Mode 3) frequencies, Hulda Clark 2500 Hz walk, and the super ParaZapper® MX mode, Three single frequency modes of 10,000 Hz, 6,000 Hz, and 5,000 Hz, 464 Hz Candida mode, Ultimate Zapper Mode ( actually far better than theirs ), and the 66.67 percent duty cycle mode. There is not any need to shop and compare any more. Get 12 different zappers in one with a total of 47 frequencies.
Prices and Buy UZI-3c Now
The board shown above is the MY-3, however, the UZI-3 has the same offset > 0.5 volts but a higher voltage waveform ( 10.5 volts rather than 9.0 volts ).
NOTE: The lower line marks 0.0 volts ( zero volts ).
Why are multi frequencies important?
The basis of the zapper's operation is that it produces a fundemental frequency that produces many harmonics reaching high into the range between 100 kHz to 1000 kHz. A harmonic is a frequency that is twice, three times, four times, or many times the base frequency. The square wave produced by zappers contains all of the odd harmonics ( 3 times, 5 times, 7 times the base frequency, etc., up to the frequency limit of the output device). This is the one real reason that there is not any single "one frequency" that works for everything. There are some better frequencies that appear to be better than others in producing a Clark spectrum but it actually takes over 40 base frequencies to get almost all of the microbes listed in the Clark frequency list. Even then, it should be noted that the Rife frequency list completely disagrees with the Clark frequencies. For this reason, we provide some of both of the Rife and Clark Frequencies to increase the chances of successfully eliminating any microbe that may be causing problems.
An Important note abut using multi-frequency zappers:
See warnings and notices at the bottom of the page.
Confusion over how many hours or minutes to zap?
There are some who are questioning about the need to zap for many long hours. This is understandable but it is rarely needed to be zapping for long periods of time.
My experience is that I often go for weeks or months without zapping and when I do need to zap, it is usually for only 1 or 2 hours and often only once or once a day for a few days.
For example, If I feel something coming on, when I get chills, start sneezing, get that itch in the eye, or a sore throat, I will usually stop and use the zapper "off-label" for an hour or so and that often does the job. See
However, there has been a few times when I had serious infections that are approaching or turning into sepsis. That is when I will usually zap for several hours a day, often at night. Sometimes, if it is bad, I will just turn the zapper on and go to sleep. Care must be used when doing this, due to a chance of skin burns from the cloth or paper towels getting dry.
On the other hand, If I was facing a more serious issue such as threatened immunity from serious viral disorders, I would likely just turn the zapper on and use around the clock, only turning off long enough to change the battery and replace the paper towels.
Also, you do not have to do all the modes, you should only use the modes or frequencies that are needed.
If you do not know what you need to use, then try one of the general purpose modes.
Some who have serious concerns may want to use the zapper more extensively.
Hulda Clark's original 7 minutes on, 20 minutes off vs ParaZapper
In her early books, Dr. Clark stated that all you needed was to zap for 7 minutes, rest for 20, and repeat 3 times.
Later, it was found that zapping for 10 minutes could produce slightly better results. It was also found that adding a separate second frequency could also improve results. Soon, there was advanced zappers with 8, 10, or even more frequencies being produced.
These additional frequencies required additional zapping time. Using 8 different frequencies required almost a full hour but in some cases, it was found to be worth it as in severe cases, it could produce better results.
Then some wondered about all the zapping times and additional frequencies, thinking that the user always had to use these advance zappers for long periods of time.
The answer to this is that it is not true. With the advanced multi-frequency zappers, you can still do the 7 minutes on and 20, 25, or 30 minutes off, repeat 3, 4, or 5 times. Whatever you wish.
The advantage to these multi-frequency zappers is that should you need to, you can always use it for the longer periods, or for the traditional times. It is your choice.
With the old single frequency zappers, you have no choice. If that frequency does not work well enough, you are just out of luck. That is just one reason that early users were not so happy with the zapper.
What about high duty cycles that some claim are better?
The Duty Cycle is the ratio of the positive pulse of the output waveform to the low side of the waveform. A true square wave is 50 percent positive and 50 percent low. Anything else is actually a rectangular wave. While some sellers claim that having a duty cycle which is higher than 66 percent will produce both odd and even harmonics, this is a misguided interpretation and is completely false except for 1 specific setting. When the duty cycle is exactly 2 to 1, then there will be an exact set of frequencies that includes both the odd and some of the even harmonics but it should be noted that each will only be a part of full strength. Additionally, if the duty cycle is not just right, the frequencies can actually interfere with each other and actually reduce effectiveness. If you buy a unit with a high duty cycle, make sure that it is microprocessor based for accuracy because having the exact frequency and the exact duty cycle makes all the difference. Zappers that use a 555 series chip for timing are not accurate enough to guarantee the right results in each and every unit so it is hit or miss. For your testing purposes, we include both the 90 percent duty cycle ( Mode 10 ) and the 66.6 percent duty cycle ( Mode 11 ) in a high quality unit with microprocessor precision and accuracy. Anyhow, these modes are all in one unit for you to test and compare.
Warning:
This product is not intended for use with a power adaptor that connects to AC power. If you use one, it should be EN60601 rated if there is any chance of contact with humans, for other uses, a standard power supply will do, and should not exceed 8.5 volts output. A higher voltage may destroy the internal electronics of this unit. The current requirement is less than 50 milliamperes and the unit should work with adapters as low as 7.0 volts.
When observed under the microscope, the electrical current appears to explode almost all of the micro-organisms present.
Zapper videos for the UZI-3
WHY I'm Buying an UZI 3 PARAZAPPER
Parazapper UZI 3 Review
ParaZapper® UZI 3 Tested, OUTSTANDING ACCURACY
Prices and Buy UZI-3c Now
Includes instructions for operation.
MODE
|
Frequencies: For more information, refer to the Rife CAFL
|
Duration
|
Mode 1
|
Rife 2.0 - 2.7 kHz range
Freq 1 2280 +/- 11 Hz
Freq 2 2128 +/- 11 Hz
Freq 3 2489 +/- 11 Hz
Freq 4 2000 +/- 11 Hz
Freq 5 2127 +/- 11 Hz
Freq 6 2720 +/- 11 Hz
Freq 7 2170 +/- 11 Hz
Freq 8 2008 +/- 11 Hz
Stop and off 5 seconds, 3 - 1 second pulses and repeat
This mode covers a broad range and is general purpose.
Note: Use for 7.0 to 28 minutes on, 15-20 minutes off, repeat 3 times. Repeating 4 times will improve effectiveness.
Note: Since each frequency lasts for 7.0 minutes, 7 minutes will only provide the first 2 frequencies. It takes 28 minutes to get all eight frequencies.
Note that due to the accuracy of the microprocessor generated signal,
most units are within 3 Hz of the specified frequency.
|
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
|
Mode 2
|
Clark 30 kHz range provides a range of frequencies
Freq 1 30500 +/- 250 Hz
Freq 2 30000 +/- 250 Hz
Freq 3 31600 +/- 300 Hz
Freq 4 33000 +/- 300 Hz
Stop and off 5 seconds, 3 - 1 second pulses and repeat
Mode 2 will blink the Mode/Battery LED 2 Flashes every 2 seconds
Note: Use for 65 minutes on. May be repeated 3 times or more with 15-20 minutes off between repeats or may be used continuous for several hours if so desired. Repeating 4 times will improve effectiveness. Also, using for 1 hour continuous works even better.
Note that due to the accuracy of the microprocessor generated signal,
most units are within 150 Hz of the specified frequency.
|
7.0 min
7.0 min
7.0 min
7.0 min
|
Mode 3
|
Croft Terminator range
Freq 15.2 Hz +/- 0.2 Hz
Stop and off 5 seconds, 3 - 1 second pulses and repeat
Mode 3 will blink the Mode/Battery LED 3 Flashes every 2 seconds
Note: Use for 7 minutes on, 15-20 minutes off, repeat 3 times. Repeating 4 times will improve effectiveness.
Important Note: This is a very low frequency that will feel much stronger than
the others if the electrodes come into contact with the body. The signal is actually
not any stronger, it just feels stronger due to normal nerve physiology. However, due
to this sensitivity, it is strongly advised to keep this frequency away from accidental
contact with either the chest area near the heart, or the head area, including the jaws
and neck and especially keep it away from the eyes.
|
7.0 min
|
Mode 4
|
Rife 660-880 Hz range
Freq 1 728 +/- 7 Hz
Freq 2 787 +/- 8 Hz
Freq 3 880 +/- 8 Hz
Freq 4 800 +/- 8 Hz
Freq 5 727 +/- 7 Hz
Freq 6 660 +/- 7 Hz
Freq 7 832 +/- 8 Hz
Freq 8 780 +/- 8 Hz
Stop and off 5 seconds, 3 - 1 second pulses and repeat
Rife Broad Range general purpose covers the most important frequencies.
Mode 4 will blink the Mode/Battery LED 4 Flashes every 2 seconds
Note: Use for 60 minutes on, 15-20 minutes off, repeat 3 times. Repeating 4 times will improve effectiveness. Or use for 1 hour continuous.
Note: Since each frequency lasts for 7.0 minutes, 7 minutes will only provide the first 2 frequencies. It takes 28 minutes to get all eight frequencies.
Note that due to the accuracy of the microprocessor generated signal,
most units are within 2 to 4 Hz of the specified frequency.
|
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
|
Mode 5
|
2.5 kHz Hulda Clark walk Mode
Set 1
Freq 1 2500 +/- 10 Hz Most units are +/- 4 Hz
Freq 2 2503 +/- 10 Hz Most units are +/- 4 Hz
Freq 3 2505 +/- 10 Hz Most units are +/- 4 Hz
Freq 4 2508 +/- 10 Hz Most units are +/- 4 Hz
Freq 5 2511 +/- 10 Hz Most units are +/- 4 Hz
Freq 6 2514 +/- 10 Hz Most units are +/- 4 Hz
Freq 7 2496 +/- 10 Hz Most units are +/- 4 Hz
Freq 8 2492 +/- 10 Hz Most units are +/- 4 Hz
Freq 9 2489 +/- 10 Hz Most units are +/- 4 Hz
Freq 10 2486 +/- 10 Hz Most units are +/- 4 Hz
Repeats cycle
Mode 5 will blink the Mode/Battery LED 1 long flash and 1 quick flash every 2 seconds
You may use this for 70 minutes on, 1 time daily, but, using it for 70 minutes, repeat 3 times should produce better results.
Note: Use for 7.0 to 70 minutes on, 15-20 minutes off, repeat 3 times. Repeating 4 times will improve effectiveness.
Note: Since each frequency lasts for 7.0 minutes, 7 minutes will only provide the first frequency. 14 minutes will provide 2 frequencies It takes 70 minutes to get all 10 frequencies.
Note that due to the accuracy of the microprocessor generated signal,
most units are within 4 Hz of the specified frequency but the guaranteed accuracy is +/- 11 Hz.
|
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
|
Mode 6
|
MX Mode
Set 1
MX mode has 8 special frequencies between 2000 Hz and 2500 Hz. Provides Broad range coverage.
Repeats sequence
Mode 6 will blink the Mode/Battery LED 1 long flash every and 2 quick flashes 2 seconds
You may use this for 60 minutes on, 1 time daily, but, using it for 60 minutes, repeat 3 times should produce better results.
Note: Use for 30 minutes or 60 minutes on ( 7.5 minutes for each frequency ), 15-20 minutes off, repeat 3 times. Repeating 4 times will improve effectiveness.
Note: Since each frequency lasts for 7.5 minutes, 7.5 minutes will only provide the first frequency. 30 minutes provides 4 frequencies. It takes 60 minutes to get all eight frequencies.
Note that due to the accuracy of the microprocessor generated signal,
|
7.5 min
|
Mode 7
|
10,000 Hz
Freq 10000 Hz +/- 50 Hz
Stop and off 5 seconds, 3 - 1 second pulses and repeat
Mode 7 will blink the Mode/Battery LED 2 Long Flashes every 2 seconds
Note: Use for 1 hour continuous or 7 minutes on, 15-20 minutes off, repeat 3 times. Repeating 4 times will improve effectiveness.
|
7.0 min
|
Mode 8
|
5000 Hz
Freq 5000 Hz +/- 25 Hz
Stop and off 5 seconds, 3 - 1 second pulses and repeat
Mode 8 will blink the Mode/Battery LED 2 Long Flashes every 2 seconds
Note: Use for 1 hour continuous or 7 minutes on, 15-20 minutes off, repeat 3 times. Repeating 4 times will improve effectiveness.
|
7.0 min
|
Mode 9
|
6000 Hz
Freq 6000 Hz +/- 30 Hz
Mode 9 will blink the Mode/Battery LED 2 Long Flashes every 2 seconds
Note: Use for 1 hour continuous or 7 minutes on, 15-20 minutes off, repeat 3 times. Repeating 4 times will improve effectiveness.
|
7.0 min
|
Mode 10
|
464 Hz Candida Frequency
Freq 1 464 Hz +/- 1.5 Hz Most units are +/- 0.5 Hz
Freq 2 464.5 Hz +/- 1.5 Hz Most units are +/- 0.5 Hz
Freq 3 465 Hz +/- 1.5 Hz Most units are +/- 0.5 Hz
Mode 10 will blink the Mode/Battery LED 1 Long Flashes, 1 quick flash, and another long flash every 2 seconds
Note: Preferred use for 1 hour and 5 minutes continuous, can be used 7.5 minutes on, 15-20 minutes off, repeat 3 times. Repeating 4 times will improve effectiveness.
|
7.5 min
7.5 min
7.5 min
|
Mode 11
|
Better than and Beyond the Ultimate Zapper Mode
Freq 2020 Hz +/- 0.6 percent at 90 percent duty cycle
Stop and off 5 seconds, 3 - 1 second pulses and repeat
Mode 11 will blink the Mode/Battery LED 1 Long Flash every 2 seconds
In Mode 11, the Status LED will appear to be more green than red because of the high duty cycle.
Note: Continuous use for 1 Hr 5 minutes (65 min ). Or use for 7.5 minutes on, 15-20 minutes off, repeat 3 times. Repeating 4 times will improve effectiveness.
|
7.5 min
|
Mode 12
|
66.6 percent duty cycle Mode
Freq 2020 Hz +/- 0.6 percent at 66.67 percent duty cycle high, 33.33 percent low
Stop and off 5 seconds, 3 - 1 second pulses and repeat
Mode 12 will blink the Mode/Battery LED 1 quick Flash every second
Note: Continuous use for 1 Hr 5 minutes (65 min ). Or use for 7.5 minutes on, 15-20 minutes off, repeat 3 times. Repeating 4 times will improve effectiveness.
|
7.5 min
|
|
Note: The frequencies in this unit are far more accurate than the frequencies in Rife units that select the frequency using a dial, unless a digital readout is used.
|
|
While the unit has two automatic timing modes and recycling for each frequency range, it does feature an automatic shutdown so that it can be used for continuous zapping with an automatic rest phase or it can be used for repetitive cycles with a 10 second pause between each. Power to the unit is supplied by a standard 9-volt battery and is controlled by a push-on / push-off switch. Frequency and mode selection are by momentary contact push button switch. To change modes, simply press the mode switch. The battery and mode LED's will both come on at the same time. Release the switch and the next mode will start. To change to the next mode, simply press the [Mode] switch again.
To use the Automatic Cycle mode where the unit times the frequencies, inserts a 20 minute rest phase, and then repeats the same frequency selection again, press and hold the Mode button while turning the unit on. The Battery/Mode LED will show continuous RED. Release the button and the unit will start in mode one. To change to the next mode, press the Mode button again and the next frequency mode will start.
Description of Indicators ( Status, Mode/Battery ) and switches (ON/OFF) and Mode (mode change)
Power ON switch: (ON/OFF Button)
When the ON/OFF switch is pressed, the unit will come on and always starts out in Mode 1.
Status LED: (Status) located nearest the On/Off button
Theory of operation: When the zapper output goes fully high, the green LED comes on fully and the red LED is completely off, making the status appear green. When the output signal goes low, the red LED is fully on and the green LED is completely off making the status appear red.
The status LED can be used to monitor normal operation and also to
test the UZI-3 for correct operation. When the unit is first turned on, it goes into a test mode where the Status indicators ( LEDs ) toggle between red and green for a couple of seconds so that the user can verify that both are working properly. The Status LED will normally appear yellowish or orange but there are exceptions. If the battery is completely dead or missing, the LED will be off or dark. If for some reason, the output fails, the LED will either be solid green or red.
To test the unit when operating, after verifying the start up toggle, the unit should be on and operating with the copper paddles connected but
not touching each other. In this condition, the LED will appear yellow or amber because it is flickering between red and green ( some people have difficulty in seeing the green which is why the startup test was added ). A Red Status may indicate that the paddles are shorted together, however, if the red and green paddles are not shorted, a completely red Status means that you need to contact the factory for service ONLY if both red and green are not visible during startup.
Touching the copper paddles together should cause the LED to show almost completely red due to the current load being pulled by the short circuit. This is an indicaton that the zapper output is functioning properly and providing sufficient output for best results.
In modes 1, 2, 4, 5, 6, 7, 8, and 9, the LEDs should be approximately equal ( actually, the red appears slightly stronger ) because the duty cycle is 50 percent, making the two colors combine ( red and green make yellow ).
In Mode 3, the frequency is so slow, only 15 cycles per second, that most individuals can see this in real time as the LED's change from red to green to red again.
In Mode 10, the duty cycle is 90 percent high so that the RED LED will appear to be weaker because of the high positive duty cycle,
making the Status to appear mostly green. Shorting the paddles together will make the status appear red.
In Mode 11, the output has a 66.7 percent positive duty cycle, so it also appears slightly more green, but less green than mode 5.
Mode change switch: ( MODE button )
To use the
Automatic Cycle Mode ( Not recommended ),
press and hold the Mode button while turning the unit on.
The Battery/Mode LED will show Red, release the button, and you will be in the Automatic Mode.
When the unit is first turned on, it starts in Mode 1 each time.
Pressing this [Mode] button at any time will change the current mode and will also restart the timer.
Each time that the [Mode] switch is pressed, it will cycle to the next mode which can be observed by watching the Mode/Battery LED for the number of flashes produced.
The Mode/Battery LED will flash the number of the Mode it is in every 2 seconds.
1 Quick Flash every 2 seconds = Mode 1
2 Flashes every 2 seconds = Mode 2
3 Flashes every 2 seconds = Mode 3
4 Flashes every 2 seconds = Mode 4
1 Long Flash and 1 quick Flash every 2 seconds = Mode 5
1 Long flash and 2 Quick Flashes every 2 seconds = Mode 6
1 Long Flash every 2 seconds = Mode 7
2 Long Flashes every 2 seconds = Mode 8
3 quick Flashes every 2 seconds = Mode 9
2 Long Flashes every 2 seconds = Mode 8
1 Long Flash and 3 quick Flashes every 2 seconds = Mode 8
Mode LED: (Battery / Mode) which is the Lower LED
The mode LED flashes the corresponding number of flashes for the mode that it is currently operating in as described in the Mode table above.
Which frequency? Use only 1 mode daily for 7 to 10 days.
Mode 1 has some frequencies that have been in use for many years and may be the best frequency to use first. It is equivalent to the 2000 Hz / 2500 Hz Clark frequency range as well as the Rife frequencies that are present. Use for 28 minutes on, 20 minutes off, repeat 3 times and continue this mode for 7 to 10 days.
Mode 2 (30 kHz range) is the normal Clark frequency but the other frequencies may have some advantages. Use for 14 minutes on, 20 minutes off, repeat 3 times and continue this mode for 7 to 10 days.
Mode 3 (15 Hz) may provide the best overall penetration but there are some limitations to its use. Use for 7 to 10 minutes on, 20 minutes off, repeat 3 times, or use for 1 hour continuous. Continue this mode for 7 to 10 days.
Mode 4 starts with the Rife Trio ( three main rife frequencies that are used more than any other Rife frequencies combined ) and continues with 5 additional Rife frequencies in the range of 660 Hz to 880 Hz. These frequencies should kill most any microbe over time, according to published Rife frequency lists. This range is also best for uses such as zappicating where Dr. Clark recommended 1kHz or 1000 Hz. Use for 28 minutes on, 20 minutes off, repeat 3 times and continue this mode for 7 to 10 days.
Mode 5 has the Clark 2500 Hz walk. It is equivalent to the 2500 Hz Clark frequency range but provides 10 different frequencies that are close together. Use for 1 hour continuous and continue this mode for 7 to 10 days.
Mode 6 is the MX mode ( same as ParaZapper® MX ) and has been in use for many years and may be the best mode over-all. It is equivalent to the 2000 Hz / 2500 Hz Clark frequency range. Use for 1 hour continuous or repeat 3 times with 20 minutes off rest periods. Continue this mode for 7 to 10 days.
Mode 7 (10000 Hz) has been reported to be a very popular frequency. Use for 1 hour continuous or 7 to 10 minutes on, 20 minutes off, repeat 3 times, or use for 1 hour continuous. Continue this mode for 7 to 10 days.
Mode 8 (5000 Hz) Is a special interest frequency. Use for 1 hour continuous or 7 to 10 minutes on, 20 minutes off, repeat 3 times, or use for 1 hour continuous. Continue this mode for 7 to 10 days.
Mode 9 (6000 Hz) Is a special interest frequency. Use for 1 hour continuous or 7 to 10 minutes on, 20 minutes off, repeat 3 times, or use for 1 hour continuous. Continue this mode for 7 to 10 days.
Mode 10 (464 Hz) Is a special interest frequency reported for Candida. Use for 1 hour continuous for best results. May be repeated as often as desired. Continue this mode for 7 to 10 days.
Mode 11 (2020 Hz 90 percent duty cycle) is an improved clone of the Ultimate Zapper due to Greater accuracy, Pedestal Offset, and stronger output. Use for 7 to 10 minutes on, 20 minutes off, repeat 3 times, or use for 1 hour continuous. Continue this mode for 7 to 10 days.
Mode 12 (2020 Hz 2:1) is a 66.66 percent duty cycle output for those who wish to experiment with it. Use for 7 to 10 minutes on, 20 minutes off, repeat 3 times, or use for 1 hour continuous. Continue this mode for 7 to 10 days.
Disclaimer: All statments and claims above are made in relation to killing microbes in water, such as protozoa, bacteria, fungi, algae, etc.
-
Pedestal offset is even better than the Positive offset specified by Dr. Clark.
Provides a clean positive offset of 0.5 volts minimum and no negative spikes.
-
Yes, Stabilized Pedestal Output ONLY on this ParaZapper®™ UZI-3 model guarantees NO negative pulses.
-
Yes, Super Stabilized Pedestal Output ( selectable by jumper ) ONLY on this ParaZapper®™ UZI-3 has slightly negative pulses under load but not as bad as the Ultimate Zapper.
-
Better Multi Frequency zapper 2.0 to 2.5 kHz ( 8 frequencies), 30 kHz (4 Frequencies),
15 Hz (Terminator frequency), (Rife 660 to 880 Hz - 8 frequencies), 464 Hz Candida mode, Ultimate Zapper Mode, and the 66.66 percent duty cycle.
-
Better Zapper Made in the USA of high quality parts .
-
Better Top quality wires and plugs, more compact
-
Solid wire connections, no rinky-dink alligator clips.
-
Good battery life: approx 8 to 10 hours usage (approx 15 to 20 sessions ) on a Alkaline 9 volt battery. Standard batteries do not provide sufficient power.
Can use 9 volt rechargeable batteries.
Status Indicator, Mode indicator, Low Battery LED
-
Protected against polarity reversal as well as against small over voltages.
-
Constant 10.5 - 10.8 volt output for better effectiveness.
-
Instructions for water treatment.
-
Information booklet available separately.
-
Ruggedly built for long lasting durability and reliability.
-
Some competitors models are cheaply built.
-
Best Zapper Price, Quality, Reliability, Performance .
-
Alkaline Battery included but no Sea Salt, etc.
s
3 Selections below
|
One ParaZapper® UZI-3c with copper paddles and pads, 2 rechargeable batteries and fast charger, for $439.00 US plus S+H.
|
One ParaZapper® UZI-3c with copper paddles and pads for $389.00 US plus S+H.
|
One ParaZapper® UZI-3c with copper paddles for $349.00 US plus S+H.
|
There is additional information such as comparison charts, testimonials, and videos in the menu above.
View zappers.
View accessories.
AUDIO
Warning: Although Hulda Clark claimed her zappers could not reach internal organs, including the intestines, she did not use the advanced multi-frequency ParaZapper including the 4 point contact and 3 points positive. Since these devices demonstrate greater effectiveness in inactivating microbes like bacteria. protozoa, and fungi, and some individuals have chosen to use these ParaZappers for off-label personal use on their bodies, we have noted reports of doing so may destroy much of the natural, beneficial flora in the intestines. For at least one reason, it is very important to replace your microbiome with supplemental probiotics soon after using. Generally, consuming a good yogurt containing live and active cultures of at least 5 or 6 strains of bacteria will be helpful in any respect. The company does not endorse any off-label use but believes ethical companies should let the public know about potential issues involving off-label uses.
Previous models of Hulda Clark Parasite Zapper, formerly available on paradevices and petzapper sites and since not as advanced as these models, those were considered to be superior to the other competing devices.
The following statement is true for All zappers, regardless of where purchased, not just ParaZapper.
Notice: On advice of counsel, here as well as elsewhere, sites are required to inform you that the statements and claims on this site have not been evaluated by the FDA ( Food and Drug Administration ) and are not intended to diagnose, treat, cure or prevent any disease -- not for use on humans or with pets. These easy to use battery powered devices are not offered or intended for human use and are not to diagnose or prescribe for medical or psychological conditions nor to claim to prevent, treat, mitigate or cure any conditions, nor to recommend specific products as treatment of disease or to provide diagnosis, care, treatment or rehabilitation of individuals, or apply medical, mental health or human development principles. The devices discussed herein have not undergone evaluation and/or testing by the United States FDA ( Food and Drug Administration ) or like agency of any other country. Risks which might be determined by such testing are unknown. The information on this site is not a substitute for medical or veterinary advice.
Additional Notice: These zappers are sold only for the experimental use of killing microbes in water. Any other usage is considered to be off-label and such usage is at the discretion of the user. They are not a Medical device and are not represented as such.
Hulda Clark ParaZapper sales
5537 Balboa Ct.
Pinson, AL 35126 USA
Please e-mail us at: email1 sales at huldaclarkparazapper.com
or
email2 sales at paradevices.com
We are having telephone problems. The calls often go to voice mail too quickly and we are having a problem getting the messages.
Also, the quarantine for coronavirus has left us with no one to answer the telephone
Please contact us by e-mail
Phone: 205-856-3909
866-765-5116
Phone Hours: 9:30 AM to 3:00 PM Central Time
Please Note that we do not sell by telephone but are happy to talk to you. Email is much better as:
If inquiring about an order, please include the order number / Invoice Number that should start with HCPZ ( do not add HCPZ to a number The HCPZ is part of the correct number ), The transaction number is different and not in our system.
EFAX = NO, we do not accept E-faxes due to possible risks.
N.L.