Zapper

Zapper MY-3

MY-3 Worlds Best Zapper Rife Zapper

MY-3 Rife Zapper with 25 modes and over 270 frequencies

100 percent positive offset square wave
Multiple frequencies, not sold as a medical zapper
Accurate frequencies and best zapper waveforms

Rugged and Reliable zapper
Quality workmanship, compare to energy medicine
Easy to use - Made in the US

ParaZapper™ MY Plus has been discontinued

See: MY-3 specifications

The ParaZapper™ MY ( Many in One Zapper ) PLUS is a crystal controlled, microprocessor based, multi-frequency zapper designed with improved results in consideration.

Important Notice: we are moving to a new model ( MY-3 ) with new improvements over the MY+Plus

Act fast, as orders for the MY+Plus will be upgraded to the MY-3 at no extra charge, a savings of $40.00, until the MY-3 is released. After that, the MY-3 will be priced at $429.00 US plus S&H. Buyers of the MY do not get the free upgrade.

This zapper includes 109 precise Rife frequencies and over 12 other frequencies combined, in eleven Rife frequency modes in addition to The Clark Max frequencies and the ParaZapper MX frequency set, as well as 5 special individual frequencies, in one package at an affordable cost and has an output voltage that is only 0.2 volts less than the battery and it also has Pedestal offset which is better than just positive offset. The output is strong and this unit is intended for those uses that need a stronger output as well as more numerous and more accurate frequencies. While guranteed to be within +/- 2.5 Hz for all frequencies and +/- 0.1 Hz for most, the zapper is usually +/- 0.1 Hz for most frequencies below 800 Hz, 0.25 Hz for most frequencies below 2000 Hz, due to the precision of the crystal oscillator that controls the accuracy. Both the MY Plus and the MY Plus-2 include new innovations, such as pedestal offset, that offer significant enhancements over other zappers. It has a timer with a beeper to let you know when your cycle is done. It even includes a favorite mode option that allows you to set it to start up in any of the modes provided. While the frequencies contained in this zapper are very specific to certain organisms, it should also be effective as a general purpose zapper according to Dr. Clark's statements. For that reason, we have selected 14 Clark and Rife Frequencies in the 1 kHz to 2.5 kHz Clark range, 8 MX frequencies, and 109 of the most important Rife frequencies for a total of over 120 frequencies to provide the greatest flexibility and the best available coverage in an economical, easy to use unit. Additionally, each of several modes has an alternate mode associated that allows the user to start the operation at either of two initial frequencies. The user can easily select to use half of one mode and then switch to using half of another mode. The MY Plus also has user selectable timing that applies to all frequencies. The frequencies for each mode are as follows.

New modes are:
Rife Special Mode 10 A ( P. klebsiella )
Rife Special Mode 10 B ( Helminths )
Rife Special Mode 11 A ( Borrelia / Rickettsia )
Rife Special Mode 11 B ( Immuno Virus / TLV )
Mode 12 produces 10.00 kHz ( 10,000 Hz )
Mode 15 produces 15.66 Hz which is twice the Schaumann earth resonance of 7.83 Hz

See these customer produced video about the best zapper in the world

ParaZapper MY+Plus Extreme Accuracy Proven

10000 Hertz, Your Frequency & ParaZapper MY Plus

ParaZapper My Plus, the Best device for Contact Mode

ParaZapper 'MY' Plus EXTREME ACCURACY PROVEN

Easiest Way to Use 'Rife' Contact Mode

Important Healing & Immunity, Rife, Crane & Clark

Important! While the MY Plus can be use 7 minutes on, 20 minutes off routine that was originally suggested by Dr. Clark in any mode, it is not suggested as it has been found that the MY Plus works better when used in the continuous mode. Follow the timing suggested in the mode that you select to use.

ParaZapper™ MY Plus parasite zapper

 


MODE Frequencies Duration
Mode 1 Rife Mode 1 A starts here.
Freq 1 72 +/- 0.1 Hz
Freq 2 728 +/- 0.25 Hz
Freq 3 95 +/- 0.1 Hz
Freq 4 428 +/- 0.25 Hz
Freq 5 776 +/- 0.25 Hz
Freq 6 120 +/- 0.1 Hz
Rife Mode 1 B starts here.
Freq 7 786 +/- 0.5 Hz
Freq 8 432 +/- 0.25 Hz
Freq 9 800 +/- .1 Hz
Freq 10 465 +/- .1 Hz
Freq 11 802 +/- .1 Hz
Freq 12 128 +/- 0.5 Hz

Mode 1 A and Mode 1 B produce all of the same frequencies except
for the order in which they are generated.
Mode 1 A cycles to Mode 1 B and Mode 1 B cycles to Mode 1 A.
Either Mode will cycle through all 12 frequencies.
The unit will provide a quick beep when cycling to the next mode.
After cycle completion, the unit will stop and beep several beeps,
then the unit will wait 5 seconds and repeat the same sequence of frequencies
or if in the auto mode, it will delay for about 20 minutes.

Mode 1 A will blink the Mode/Battery LED 1 Flash every 2 seconds
Mode 1 B will blink the Mode/Battery LED 2 Flashes every 2 seconds

This mode will Show

BLK

BLK

RED
on the Mode LEDs

Note that due to the accuracy of the microprocessor generated signal,
most units are within 0.5 Hz of the specified frequency in this range.

Timing: The total minimum cycle time is 90 minutes at a cycle time of 7 minutes.
A session of 90 minutes (1-1/2 hours)is recommended with a cycle time of 7 minutes.
A session of 120 minutes (2 hours)is recommended with a cycle time of 10 minutes.

This mode contains 12 of the most frequently used
Rife frequencies at 7.0 minutes each.
The cycle time may be user selected for 1, 3.5, 7, or 10 minutes for all frequencies.

It is recommended to use this unit at 7 minutes per frequency and go through all frequencies in one mode daily. Use the same mode for at least 1 week to 10 days.

7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *

7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *

*
The duration
is selectable
for 1 min,
3-1/2 min,
7 minutes,
or 10 minutes
for all
frequencies


















Mode 2 Rife Mode 2 A starts here.
Freq 1 500 +/- 0.1 Hz
Freq 2 880 +/- 0.5 Hz
Freq 3 600 +/- 0.25 Hz
Freq 4 1552 +/- 0.5 Hz
Freq 5 650 +/- 0.5 Hz
Freq 6 440 +/- 0.1 Hz
Rife Mode 2 B starts here.
Freq 7 1865 +/- 1.0 Hz
Freq 8 660 +/- 0.25 Hz
Freq 9 2008 +/- 0.5 Hz
Freq 10 676 +/- 0.5 Hz
Freq 11 2127 +/- 2.0 Hz
Freq 12 2720 +/- 3.0 Hz

Mode 2 A and Mode 2 B produce all of the same frequencies except
for the order in which they are generated.
Mode 2 A cycles to Mode 2 B and Mode 2 B cycles to Mode 2 A.
Either Mode will cycle through all 12 frequencies.
The unit will provide a quick beep when cycling to the next mode.
After cycle completion, the unit will stop and beep several beeps,
then the unit will wait 5 seconds and repeat the same sequence of frequencies
or if in the auto mode, it will delay for about 20 minutes.

Mode 2 A will blink the Mode/Battery LED 1 Flash every 2 seconds
Mode 2 B will blink the Mode/Battery LED 2 Flashes every 2 seconds

This mode will Show

BLK

RED

BLK
on the Mode LEDs

Note that due to the accuracy of the microprocessor generated signal,
most units are within 1 Hz of the specified frequency.

Timing: The total minimum cycle time is 90 minutes at a cycle time of 7 minutes.
A session of 90 minutes (1-1/2 hours)is recommended with a cycle time of 7 minutes.
A session of 120 minutes (2 hours)is recommended with a cycle time of 10 minutes.

This mode contains 12 of the most frequently used
Rife frequencies at 7.0 minutes each.
The cycle time may be user selected for 1, 3.5, 7, or 10 minutes for all frequencies.

Intended to augment the 12 Rife frequencies in Mode 1 ( Rife Mode 1 ).

It is recommended to use this unit at 7 minutes per frequency and go through all frequencies in one mode daily. Use the same mode for at least 1 week to 10 days.

7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *

7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *

*
The duration
is selectable
for 1 min,
3-1/2 min,
7 minutes,
or 10 minutes
for all
frequencies




















Mode 3 Rife Antibacterial and Antifungal Mode 3 A starts here.
Freq 1 20 +/- 0.1 Hz
Freq 2 465 +/- 0.1 Hz
Freq 3 880 +/- 0.5 Hz
Freq 4 1550 +/- 1.0 Hz
Freq 5 784 +/- 0.25 Hz
Freq 6 727 +/- 0.25 Hz
Rife Antibacterial Mode 3 B starts here.
Freq 7 787 +/- 0.25 Hz
Freq 8 832 +/- 0.5 Hz
Freq 9 800 +/- 0.5 Hz
Freq 10 866 +/- 0.5 Hz
Freq 11 664 +/- 0.25 Hz
Freq 12 690 +/- 0.5 Hz
Mode 3 A and Mode 3 B produce all of the same frequencies except
for the order in which they are generated.
Mode 3 A cycles to Mode 3 B and Mode 3 B cycles to Mode 3 A.
Either Mode will cycle through all 12 frequencies.
The unit will provide a quick beep when cycling to the next mode.
After cycle completion, the unit will stop and beep several beeps,
then the unit will wait 5 seconds and repeat the same sequence of frequencies
or if in the auto mode, it will delay for about 20 minutes.

Mode 3 A will blink the Mode/Battery LED 1 Flash every 2 seconds
Mode 3 B will blink the Mode/Battery LED 2 Flashes every 2 seconds

This mode will Show

BLK

RED

RED
on the Mode LEDs

Note that due to the accuracy of the microprocessor generated signal,
most units are within 2.0 Hz of the specified frequency.

Timing: The total minimum cycle time is 90 minutes at a cycle time of 7 minutes.
A session of 90 minutes (1-1/2 hours)is recommended with a cycle time of 7 minutes.
A session of 120 minutes (2 hours)is recommended with a cycle time of 10 minutes.

The cycle time may be user selected for 1, 3.5, 7, or 10 minutes for all frequencies.

This mode contains the set of frequencies most commonly called for
in the Rife list to kill bacteria.

It is recommended to use this unit at 7 minutes per frequency and go through all frequencies in one mode daily. Use the same mode for at least 1 week to 10 days.

7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *

7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *

*
The duration
is selectable
for 1 min,
3-1/2 min,
7 minutes,
or 10 minutes
for all
frequencies


















Mode 4 Rife Antifungal Mode 4 A starts here.
Freq 1 72 +/- 0.1 Hz
Freq 2 254 +/- 0.1 Hz
Freq 3 422 +/- 0.11 Hz
Freq 4 582 +/- 0.25 Hz
Freq 5 1016 +/- 0.5 Hz
Freq 6 1134 +/- 0.5 Hz
Rife Antifungal Mode 4 B starts here.
Freq 7 374 +/- 0.25 Hz
Freq 8 697 +/- 0.5 Hz
Freq 9 743 +/- 0.5 Hz
Freq 10 339 +/- 0.25 Hz
Freq 11 802 +/- 0.25 Hz

Combine with Mode 3A for a more complete set as these 6 frequencies affect both bacteria and fungi.
Mode 4 A and Mode 4 B produce all of the same frequencies except
for the order in which they are generated.
Mode 4 A cycles to Mode 4 B and Mode 4 B cycles to Mode 4 A.
Either Mode will cycle through all 17 frequencies.
The unit will provide a quick beep when cycling to the next mode.
After cycle completion, the unit will stop and beep several beeps,
then the unit will wait 5 seconds and repeat the same sequence of frequencies
or if in the auto mode, it will delay for about 20 minutes.

Mode 4 A will blink the Mode/Battery LED 1 Flash every 2 seconds
Mode 4 B will blink the Mode/Battery LED 2 Flashes every 2 seconds

This mode will Show

RED

BLK

BLK
on the Mode LEDs

Note that due to the accuracy of the microprocessor generated signal,
most units are within 1 Hz of the specified frequency.

Timing: The total minimum cycle time is 84 minutes using a 7 minute cycle.
A session of 84 minutes is recommended with a cycle time of 7 minutes.
A session of 110 minutes is recommended with a cycle time of 10 minutes.

The cycle time may be user selected for 1, 3.5, 7, or 10 minutes for all frequencies.

This mode contains the set of frequencies most commonly called for
in the Rife list to kill yeast, mold, fungi.

It is recommended to use this unit at 7 minutes per frequency and go through all frequencies in one mode daily. Use the same mode for at least 1 week to 10 days.

7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *

7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *

*
The duration
is selectable
for 1 min,
3-1/2 min,
7 minutes,
or 10 minutes
for all
frequencies


















Mode 5 Rife Anti Viral Mode 5 A starts here.
Freq 1 2489 +/- 2 Hz
Freq 2 727 +/- 0.25 Hz
Freq 3 329 +/- 0.1 Hz
Freq 4 802 +/- 0.25 Hz
Freq 5 1550 +/- 1.0 Hz
Freq 6 766 +/- 10.5 Hz
Rife Anti Viral Mode 5 B starts here.
Freq 7 444 +/- 0.25 Hz
Freq 8 787 +/- 0.5 Hz
Freq 9 2128 +/- 0.5 Hz
Freq 10 800 +/- 0.25 Hz
Freq 11 465 +/- 0.25 Hz
Freq 12 1234 +/- 0.5 Hz

Mode 5 A and Mode 5 B produce all of the same frequencies except
for the order in which they are generated.
Mode 5 A cycles to Mode 5 B and Mode 5 B cycles to Mode 5 A.
Either Mode will cycle through all 10 frequencies.
The unit will provide a quick beep when cycling to the next mode.
After cycle completion, the unit will stop and beep several beeps,
then the unit will wait 5 seconds and repeat the same sequence of frequencies
or if in the auto mode, it will delay for about 20 minutes.

Mode 5 A will blink the Mode/Battery LED 1 Flash every 2 seconds
Mode 5 B will blink the Mode/Battery LED 2 Flashes every 2 seconds

This mode will Show

RED

BLK

RED
on the Mode LEDs

Note that due to the accuracy of the microprocessor generated signal,
most units are within 1 Hz of the specified frequency.

Timing: The total minimum cycle time is 90 minutes at a cycle time of 7 minutes.
A session of 90 minutes (1-1/2 hours)is recommended with a cycle time of 7 minutes.
A session of 120 minutes (2 hours)is recommended with a cycle time of 10 minutes.

This mode contains set of frequencies most commonly called for
in the Rife list to kill various virus forms at 7.0 minutes each.

The cycle time may be user selected for 1, 3.5, 7, or 10 minutes for all frequencies.

It is recommended to use this unit at 7 minutes per frequency and go through all frequencies in one mode daily. Use the same mode for at least 1 week to 10 days.

7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *

7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *

*
The duration
is selectable
for 1 min,
3-1/2 min,
7 minutes,
or 10 minutes
for all
frequencies


















Mode 6 Rife Anti Fungal Mode 6 A starts here.
Freq 1 464 +/- 0.25 Hz
Freq 2 886 +/- 0.5 Hz
Freq 3 866 +/- 0.5 Hz
Freq 4 414 +/- 0.25 Hz
Freq 5 254 +/- 0.1 Hz
Freq 6 344 +/- 0.1 Hz
Freq 7 2411 +/- 2.0 Hz
Rife Anti Fungal Mode 6 B starts here.
Freq 8 321 +/- 0.25 Hz
Freq 9 555 +/- 0.5 Hz
Freq 10 942 +/- 0.5 Hz
Freq 11 337 +/- 0.25 Hz
Freq 12 1823 +/- 2 Hz
Freq 13 666 +/- 0.25 Hz

Mode 6 A and Mode 6 B produce all of the same frequencies except
for the order in which they are generated.
Mode 6 A cycles to Mode 6 B and Mode 6 B cycles to Mode 6 A.
Either Mode will cycle through all 17 frequencies.
The unit will provide a quick beep when cycling to the next mode.
After cycle completion, the unit will stop and beep several beeps,
then the unit will wait 5 seconds and repeat the same sequence of frequencies
or if in the auto mode, it will delay for about 20 minutes.

Mode 6 A will blink the Mode/Battery LED 1 Flash every 2 seconds
Mode 6 B will blink the Mode/Battery LED 2 Flashes every 2 seconds

This mode will Show

RED

RED

BLK
on the Mode LEDs

Note that due to the accuracy of the microprocessor generated signal,
most units are within 1 Hz of the specified frequency.

Timing: The total minimum cycle time is 98 minutes at a cycle time of 7 minutes.
A session of 98 minutes is recommended with a cycle time of 7 minutes.
A session of 130 minutes is recommended with a cycle time of 10 minutes.

This mode contains the set of frequencies most commonly called for
in the Rife list to kill various mold and fungal forms.

It is recommended to use this unit at 7 minutes per frequency and go through all frequencies in one mode daily. Use the same mode for at least 1 week to 10 days.

7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min




























Mode 7 Rife Mode 7 A starts here.
Freq 1 666 +/- 0.25 Hz
Freq 2 776 +/- 0.5 Hz
Freq 3 20 +/- 0.1 Hz
Freq 4 802 +/- 0.25 Hz
Freq 5 1550 +/- 1.0 Hz
Freq 6 884 +/- 0.5 Hz
Rife Mode 7 B starts here.
Freq 7 727 +/- 0.25 Hz
Freq 8 880 +/- 0.5 Hz
Freq 9 787 +/- 0.5 Hz
Freq 10 522 +/- 0.25 Hz
Freq 11 625 +/- 0.25 Hz
Freq 12 732 +/- 0.25 Hz

Mode 7 A and Mode 7 B produce all of the same frequencies except
for the order in which they are generated.
Mode 7 A cycles to Mode 7 B and Mode 7 B cycles to Mode 7 A.
Either Mode will cycle through all 10 frequencies.
The unit will provide a quick beep when cycling to the next mode.
After cycle completion, the unit will stop and beep several beeps,
then the unit will wait 5 seconds and repeat the same sequence of frequencies
or if in the auto mode, it will delay for about 20 minutes.

Mode 7 A will blink the Mode/Battery LED 1 Flash every 2 seconds
Mode 7 B will blink the Mode/Battery LED 2 Flashes every 2 seconds

This mode will Show

RED

RED

RED
on the Mode LEDs

Note that due to the accuracy of the microprocessor generated signal,
most units are within 1 Hz of the specified frequency.

Timing: The total minimum cycle time is 90 minutes at a cycle time of 7 minutes.
A session of 90 minutes (1-1/2 hours)is recommended with a cycle time of 7 minutes.
A session of 120 minutes (2 hours)is recommended with a cycle time of 10 minutes.

This mode contains 12 additional frequently used
Rife frequencies at 7.0 minutes each.
The cycle time may be user selected for 1, 3.5, 7, or 10 minutes for all frequencies.

It is recommended to use this unit at 7 minutes per frequency and go through all frequencies in one mode daily. Use the same mode for at least 1 week to 10 days.

7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *

7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *

*
The duration
is selectable
for 1 min,
3-1/2 min,
7 minutes,
or 10 minutes
for all
frequencies

















Mode 8 Clark Mode 8 A starts here.
Freq 1 1000 +/- 0.25 Hz
Freq 2 2350 +/- 0.5 Hz
Freq 3 1250 +/- 0.25 Hz
Freq 4 2300 +/- 1.0 Hz
Freq 5 1500 +/- 1.0 Hz
Freq 6 2100 +/- 2.0 Hz
Freq 7 1600 +/- 1.0 Hz
Clark Mode 8 B starts here.
Freq 8 2175 +/- 1.0 Hz
Freq 9 2050 +/- 1.0 Hz
Freq 10 2150 +/- 1.0 Hz
Freq 11 2075 +/- 1.0 Hz
Freq 12 2458 +/- 1.0 Hz
Freq 13 2006 +/- 1.0 Hz
Freq 14 2059 +/- 1.0 Hz

Mode 8 A and Mode 8 B produce all of the same frequencies except
for the order in which they are generated.
Mode 8 A cycles to Mode 8 B and Mode 8 B cycles to Mode 8 A.
Either Mode will cycle through all 10 frequencies.
The unit will provide a quick beep when cycling to the next mode.
After cycle completion, the unit will stop and beep several beeps,
then the unit will wait 5 seconds and repeat the same sequence of frequencies
or if in the auto mode, it will delay for about 20 minutes.

Mode 8 A will blink the Mode/Battery LED 1 Flash every 2 seconds
Mode 8 B will blink the Mode/Battery LED 2 Flashes every 2 seconds

This mode will Show

BLK

BLK

BLK
on the Mode LEDs

Note that due to the accuracy of the microprocessor generated signal,
most units are within 1 Hz of the specified frequency.

Timing: The total cycle time to produce all 14 frequencies is 105 minutes.
A session of 105 minutes is recommended with a cycle time of 7 minutes.
A session of 140 minutes is recommended with a cycle time of 10 minutes.

This mode will through the production of harmonics, reach 97 percent of the frequencies
provided in Dr. Hulda Clark's frequency list within a narrow margin.

It is recommended to use this unit at 7 minutes per frequency and go through all frequencies in one mode daily. Use the same mode for at least 1 week to 10 days.

7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *

7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *

*
The duration
is selectable
for 1 min,
3-1/2 min,
7 minutes,
or 10 minutes
for all
frequencies
















Mode 9 MX Mode 9 starts here.
Freq 1 2422 +/- 1.0 Hz
Freq 2 2327 +/- 2.0 Hz
Freq 3 2246 +/- 2.0 Hz
Freq 4 2177 +/- 1.0 Hz
Freq 5 2379 +/- 1.0 Hz
Freq 6 2290 +/- 2.0 Hz
Freq 7 2214 +/- 2.0 Hz
Freq 8 2148 +/- 2.0 Hz

Mode 9 produces all of the same basic frequencies as the old ParaZapper MX.
The unit will provide a quick beep after frequency 4 and after frequency 8.
After cycle completion, the unit will stop and beep several beeps,
then the unit will wait 5 seconds and repeat the same sequence of frequencies
or if in the auto mode, it will delay for about 20 minutes.

Mode 9 will blink the Mode/Battery LED 1 long Flash every 2 seconds
This mode will Show

RED

RED

BLK
on the Mode LEDs

Note that due to the accuracy of the microprocessor generated signal,
most units are within 1 Hz of the specified frequency.

Timing: The total cycle time to produce all 8 frequencies is 60 minutes.
A session of 60 minutes (1 hour)is recommended with a cycle time of 7 minutes.
A session of 80 minutes (1 hour 20 minutes)is recommended with a cycle time of 10 minutes.

This mode duplicates the frequencies
provided in ParaZapper MX.

It is recommended to use this unit at 7 minutes per frequency and go through all frequencies in one mode daily. Use the same mode for at least 1 week to 10 days.

7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *
7.0 min *

*
The duration
is selectable
for 1 min,
3-1/2 min,
7 minutes,
or 10 minutes
for all
frequencies
















Mode 10 Rife Special Mode 10 A ( P. klebsiella ) starts here.
Freq 1 412 +/- 0.10 Hz
Freq 2 413 +/- 0.10 Hz
Freq 3 746 +/- 0.25 Hz
Freq 4 765 +/- 0.25 Hz
Freq 5 840 +/- 0.25 Hz
Freq 6 783 +/- 0.25 Hz
Freq 7 818 +/- 0.25 Hz
Freq 8 779 +/- 0.25 Hz

In this Mode, part A does not roll over to part B but loops back to the start of Rife Mode 10a.

Rife Special Mode 10 B ( Helminths ) starts here.
Freq 9 125 +/- 0.05 Hz
Freq 10 440 +/- 0.1 Hz
Freq 11 444 +/- 0.1 Hz
Freq 12 344 +/- 0.1 Hz
Freq 13 112 +/- 0.05 Hz
Freq 14 152 +/- 0.05 Hz
Freq 15 524 +/- 0.20 Hz
Freq 16 712 +/- 0.25 Hz
Freq 17 651 +/- 0.25 Hz
Freq 18 128 +/- 0.05 Hz
Freq 19 422 +/- 0.10 Hz

In this Mode, part B does not roll over to part A but loops back to the start of Rife Mode 10b.

Mode 10 A and Mode 10 B are independent of each other.
Mode 10 A does not cycle to Mode 10 B and Mode 10 B does not cycle to Mode 10 A.

Each mode will provide 4 quick beeps when cycling back to the start.
then the unit will wait 5 seconds and repeat the same sequence of frequencies
or if in the auto mode, it will delay for about 20 minutes.

Mode 10 A will blink the Mode/Battery LED 1 Flash every 2 seconds
Mode 10 B will blink the Mode/Battery LED 2 Flashes every 2 seconds

This mode will Show

RED

RED

BLK
on the Mode LEDs

Note that due to the accuracy of the microprocessor generated signal,
most units are within 0.05 percent of the specified frequency.

Timing: A session of 60 minutes is recommended with a cycle time of 7 minutes in Mode 10a.
A session of 85 minutes is recommended with a cycle time of 7 minutes in Mode 10b.
This mode contains the set of frequencies most commonly called for
in the Rife list to kill various mold and fungal forms.

It is recommended to use this unit at 7 minutes per frequency and go through all frequencies in one mode daily. Use the same mode for at least 1 week to 10 days.

7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min




7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min




























Mode 11 Rife Special Mode 11 A ( Borrelia / Rickettsia ) starts here.
Freq 1 2720 +1.6/-0 Hz
Freq 2 1583 +1.0/-0 Hz
Freq 3 500 +/- 0.25 Hz
Freq 4 2016 +/- 0.5 Hz
Freq 5 1600 +/- 0.25 Hz
Freq 6 1800 +0/-1.5 Hz
Freq 7 254 +/- 0.25 Hz
Freq 8 338 +/- 0.25 Hz
Freq 9 239 +/- 0.05 Hz
Freq 10 884 +/- 0.5 Hz
Freq 11 693 +/- 0.1 Hz

In this Mode, part A does not roll over to part B but loops back to the start of Rife Mode 10a.

Rife Special Mode 11 B ( Immuno Virus / TLV ) starts here.
Freq 12 683 +/- 0.1 Hz
Freq 13 3554 +0/-1.5 Hz
Freq 14 714 +/- 0.05 Hz
Freq 15 830 +/- 0.20 Hz
Freq 16 450 +/- 0.25 Hz
Freq 17 418 +/- 0.25 Hz
Freq 18 249 +/- 0.05 Hz
----- Beeps here -----
Freq 19 633 +/- 0.10 Hz
Freq 20 837 +/- 0.10 Hz
Freq 21 776 +/- 0.10 Hz
Freq 22 392 +/- 0.10 Hz
Freq 23 111 +/- 0.10 Hz
Freq 24 1220 +/- 0.10 Hz

In this Mode, part B does not roll over to part A but loops back to the start of Rife Mode 11b.

Mode 11 A and Mode 11 B are independent of each other.
Mode 11 A does not cycle to Mode 11 B and Mode 11 B does not cycle to Mode 11 A.
Each mode will provide 4 quick beeps when cycling back to the start.
then the unit will wait 5 seconds and repeat the same sequence of frequencies
or if in the auto mode, it will delay for about 20 minutes.

Mode 11 A will blink the Mode/Battery LED 1 Flash every 2 seconds
Mode 11 B will blink the Mode/Battery LED 2 Flashes every 2 seconds

This mode will Show

RED

BLK

RED
on the Mode LEDs

Note that due to the accuracy of the microprocessor generated signal,
most units are within 0.05 percent of the specified frequency.

Timing: A session of 60 minutes is recommended with a cycle time of 7 minutes in Mode 11a.
A session of 85 minutes is recommended with a cycle time of 7 minutes in Mode 11b.
This mode contains the set of frequencies most commonly called for
in the Rife list to kill various viral forms.

It is recommended to use this unit at 7 minutes per frequency and go through all frequencies in one mode at least once daily. Use the same mode for at least 1 week to 10 days.

7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min



7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min

7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min
7.0 min




























Mode 12 Mode 12 starts here.
Freq 1 10.00 kHz +/- 0.5 Hz

Mode 12 produces 10.00 kHz
The unit will provide a quick beep when the Mode times out.
After cycle completion, repeat the same frequency again.
This mode does not have an automatic time out.

Mode 12 will blink the Mode/Battery LED 1 long Flash followed by 1 quick flash every 2 seconds
This mode will Show

RED

RED

RED
on the Mode LEDs


7.0 min *

*
The duration
is selectable
for 1 min,
3-1/2 min,
7 minutes,
or 10 minutes
for all
frequencies




Mode 13 Mode 13 starts here.
Freq 1 3.915 Hz +/- 0.001 Hz

Mode 13 produces 3.915 Hz which is one half of the Schaumann earth resonance of 7.83 Hz
The unit will provide a quick beep when the Mode times out.
After cycle completion, repeat the same frequency again.
This mode does not have an automatic time out.

Mode 13 will blink the Mode/Battery LED 1 long Flash followed by 1 quick flashes every 2 seconds
This mode will Show

RED

RED

RED
on the Mode LEDs


7.0 min *

*
The duration
is selectable
for 1 min,
3-1/2 min,
7 minutes,
or 10 minutes
for all
frequencies




Mode 14 Mode 14 starts here.
Freq 1 4.000 Hz +/- 0.002 Hz

Mode 14 produces 4.000 Hz
The unit will provide a quick beep when the Mode times out.
then the unit will repeat the same frequency.
This mode does not have an automatic time out.

Mode 14 will blink the Mode/Battery LED 1 long Flash followed by 2 quick flashes every 2 seconds
This mode will Show

RED

RED

RED
on the Mode LEDs


7.0 min *

*
The duration
is selectable
for 1 min,
3-1/2 min,
7 minutes,
or 10 minutes
for all
frequencies




Mode 15 Mode 15 starts here.
Freq 1 15.66 Hz +/- 0.01 Hz

Mode 15 produces 15.66 Hz which is twice the Schaumann earth resonance of 7.83 Hz
The unit will provide a quick beep when the Mode times out.
After cycle completion, repeat the same frequency again.
This mode does not have an automatic time out.

Mode 15 will blink the Mode/Battery LED 1 long Flash followed by 3 quick flashes every 2 seconds
This mode will Show

RED

RED

RED
on the Mode LEDs


7.0 min *

*
The duration
is selectable
for 1 min,
3-1/2 min,
7 minutes,
or 10 minutes
for all
frequencies




Mode 16 Mode 16 starts here.
Freq 1 1.00 Hz +/- 0.0001 Hz

Mode 16 produces 1.000 Hz
The unit will provide a quick beep when the Mode times out.
After cycle completion, repeat the same frequency again.
This mode does not have an automatic time out.

Mode 16 will blink the Mode/Battery LED 1 long Flash followed by 4 quick flashes every 2 seconds
This mode will Show

RED

RED

BLK
on the Mode LEDs


7.0 min *

*
The duration
is selectable
for 1 min,
3-1/2 min,
7 minutes,
or 10 minutes
for all
frequencies




  Note: The frequencies in this unit are far more accurate than the frequencies in Rife
units that select the frequency using a dial, unless a digital readout is used.

Note: While the frequencies listed for this unit are expected to be for certain parasites, there has not been
any scientific tests run to validate that these frequencies actually have any effect on those specific
parasites or any other parasites for that matter. This unit is only presented as a tool for experimentation.
 

The unit has automatic timing and recycling for each frequency and it does feature an automatic shutdown so that it can be used for continouos zapping. Power to the unit is supplied by a Alkaline or special Rechargeable 9-volt battery and is controlled by a push-on / push-off switch. The output voltage is near to the actual battery voltage and the battery can go down to 7.8 volts before requiring replacement or recharging. Frequency selection is by momentary contact push button switch. To change modes, simply press the mode switch. The battery and mode LED's will both come on at the same time. Release the switch and the next mode will start.

Description of Indicators ( Status, Mode/Battery ) and switches (ON/OFF) and Mode (mode change) Power ON switch: (ON/OFF Button)
When the ON/OFF switch is pressed, the unit will come on and will first flash the timing selection for 1 second. It then turns on the center LED while it is waiting for the crystal oscillator to start. If the crystal oscillator does not start, the unit will reboot and try again. If the unit cycles repeatedly like this, there is a problem that requires factory assistance. Once the crystal oscillator starts, the unit always starts out in the Favorite Mode which in a new unit, is Mode 1A. The user may change the Favorite mode to any other mode at any time. Once a new favorite mode has been set, the unit will always start up in that mode.

Status LED: (Status) located nearest the On/Off button

The status LED can be used to monitor normal operation and also to test the unit for correct operation. The Status LED will normally appear yellowish or orange but there are exceptions. If the battery is completely dead or missing, the LED will be off or dark. If for some reason, the output fails, the LED will either be solid green or red.
To test the unit when operating, the unit should be on and operating with the copper paddles connected but not touching each other. In this condition, the LED will appear yellow or amber because it is flickering between red and green. A Red Status may indicate that the paddles are shorted together, however, if the red and green paddles are not shorted, a completely red Status means that you need to contact the factory for service.
Touching the copper paddles together should cause the LED to show almost completely red due to the current load being pulled by the short circuit. This is an indicaton that the zapper output is functioning properly and providing sufficient output for best results.
In certain frequencies ( 30 Hz and lower ), the RED and GREEN LEDs will ppear to flicker because of the low frequency. The LEDs actually flicker in all modes but they flicker faster than the eye can perceive.

Mode change switch: ( MODE button )
When the unit is first turned on, it starts in the Favorite Mode each time. The unit is shipped with the favorite mode set to mode 1A.
Pressing this [Mode] button at any time will change from the current mode to the next mode in sequence and will also restart the timer. Pressing and holding the switch in until a beep is heard will program the mode as Favorite.

Favorite Mode
When changing modes, if the Mode button is pressed for more than 2 seconds, the unit will beep and Favorite Mode will be erased. After the mode button is released, the unit will beep 4 softer beeps and then start in the Favorite mode that was selected and the unit will start in that mode each time the unit is turned on.

Each time that the [Mode] switch is pressed, it will cycle to the next mode which can be observed by watching the Mode LEDs for the pattern produced.

The Mode/Battery LED will flash either one or two flashes every 2 seconds.

Mode 1A through 8A will produce a quick Flash every 2 seconds
2 Flashes every 2 seconds in Mode 1B through 8B.
Mode 9 does not provide a B option.
Mode LED: (Battery / Mode) which is the Lower LED
The mode LED flashes once or twice per every 2 seconds.

Mode indicator array

RED

BLK

BLK
consists of 3 RED LEDs that are turned on or off to show a code for the mode that it is currently operating in as described in the Mode table above.

Setup
To set up timing and/or Favorite Mode, turn the unit off, Press the Mode button and while holding the mode button in, turn the unit on.

Every couple of seconds, the unit will Beep and flash the LED's in the Mode Indicator array.


BLK

BLK

BLK
means that each frequency will continue for 1.0 minute ( actually, about 62 seconds )


BLK

BLK

Red
means that each frequency will continue for 3.5 minutes ( actually, about 3 Minutes 37 seconds )


BLK

Red

BLK
means that each frequency will continue for 7.5 minutes ( actually, about 7 Minutes 37 seconds )


Red

BLK

BLK
means that each frequency will continue for 10 minutes ( actually, about 10 Minutes 20 seconds )


Red

Red

Red
means that the frequency has defaulted to 7.5 minutes ( actually, about 7 Minutes 37 seconds )

Release the Mode button when the correct timing mode is selected. This should be followed by 4 soft beeps to indicate programming success.

Now that the Timing is selected, you may change the default mode by pressing the mode button in.

If the unit is currently in mode 1A.
Each button press will advance it to the next mode selection, 1B, 2A, 2B, etc. It issues a series of beeps corresponding to the number of the mode selected each time the mode button is pressed and the mode is advanced. Modes 11 and 12 only beep 8 times.

When you reach the mode that you wish to save as favorite mode, hold the button in until the the unit starts to provide a second set of beeps.
Once the set of beeps has been started, release the button and the unit should remain in the selected mode and after the initial set of beeps, there is a second set of softer beeps to indicate programming success. If it switches back to mode 1A, the old data was erased and you just need to program the frequency the same way again.

This time, the unit will remain in the favorite mode and the timing that you selected. It will also use these settings each time that you turn the unit on until it is changed.

Automatic 20 minute rest timing
To use this function, with the unit powered off, press and hold the Mode button and then turn the power on. Immediately release the Mode button, the unit will issue a long beep and start operating in the Automatic mode with the previously set timing and mode.

Disclaimer: All statments and claims above are made in relation to killing microbes in water, such as protozoa, bacteria, fungi, algae, etc.

AUDIO
Warning: Although Hulda Clark claimed her zappers could not reach internal organs, including the intestines, she did not use the advanced multi-frequency ParaZapper including the 4 point contact and 3 points positive. Since these devices demonstrate greater effectiveness in inactivating microbes like bacteria. protozoa, and fungi, and some individuals have chosen to use these ParaZappers for off-label personal use on their bodies, we have noted reports of doing so may destroy much of the natural, beneficial flora in the intestines. For at least one reason, it is very important to replace your microbiome with supplemental probiotics soon after using. Generally, consuming a good yogurt containing live and active cultures of at least 5 or 6 strains of bacteria will be helpful in any respect. The company does not endorse any off-label use but believes ethical companies should let the public know about potential issues involving off-label uses.

Previous models of Hulda Clark Parasite Zapper, formerly available on paradevices and petzapper sites and since not as advanced as these models, those were considered to be superior to the other competing devices.

The following statement is true for All zappers, regardless of where purchased, not just ParaZapper.

Notice: On advice of counsel, here as well as elsewhere, sites are required to inform you that the statements and claims on this site have not been evaluated by the FDA ( Food and Drug Administration ) and are not intended to diagnose, treat, cure or prevent any disease -- not for use on humans or with pets. These easy to use battery powered devices are not offered or intended for human use and are not to diagnose or prescribe for medical or psychological conditions nor to claim to prevent, treat, mitigate or cure any conditions, nor to recommend specific products as treatment of disease or to provide diagnosis, care, treatment or rehabilitation of individuals, or apply medical, mental health or human development principles. The devices discussed herein have not undergone evaluation and/or testing by the United States FDA ( Food and Drug Administration ) or like agency of any other country. Risks which might be determined by such testing are unknown. The information on this site is not a substitute for medical or veterinary advice.

Additional Notice: These zappers are sold only for the experimental use of killing microbes in water. Any other usage is considered to be off-label and such usage is at the discretion of the user. They are not a Medical device and are not represented as such.


Hulda Clark ParaZapper sales
5537 Balboa Ct.
Pinson, AL 35126 USA

Please e-mail us at: email1 sales at huldaclarkparazapper.com
or email2 sales at paradevices.com


We are having telephone problems. The calls often go to voice mail too quickly and we are having a problem getting the messages.
Also, the quarantine for coronavirus has left us with no one to answer the telephone
Please contact us by e-mail

Phone: 205-856-3909
866-765-5116
Phone Hours: 9:30 AM to 3:00 PM Central Time

Please Note that we do not sell by telephone but are happy to talk to you. Email is much better as:
If inquiring about an order, please include the order number / Invoice Number that should start with HCPZ ( do not add HCPZ to a number The HCPZ is part of the correct number ), The transaction number is different and not in our system.

EFAX = NO, we do not accept E-faxes due to possible risks.

Accept Credit Cards Online


N.L.